visomat-data-downloader: fix a missing parenthesis in an output string
[visomat-utils.git] / contrib / lsusb-visomat-double-comfort.log
1 Bus 002 Device 004: ID 1247:00f8  
2 Device Descriptor:
3   bLength                18
4   bDescriptorType         1
5   bcdUSB               1.10
6   bDeviceClass            2 Communications
7   bDeviceSubClass         0 
8   bDeviceProtocol         0 
9   bMaxPacketSize0        64
10   idVendor           0x1247 
11   idProduct          0x00f8 
12   bcdDevice            0.01
13   iManufacturer           1 JAPAN PRECISION INSTRUMENTS
14   iProduct                2 USB COMMUNICATION BRIDGE
15   iSerial                 3 
16   bNumConfigurations      1
17   Configuration Descriptor:
18     bLength                 9
19     bDescriptorType         2
20     wTotalLength           74
21     bNumInterfaces          2
22     bConfigurationValue     1
23     iConfiguration          1 JAPAN PRECISION INSTRUMENTS
24     bmAttributes         0x80
25       (Bus Powered)
26     MaxPower               30mA
27     Interface Descriptor:
28       bLength                 9
29       bDescriptorType         4
30       bInterfaceNumber        0
31       bAlternateSetting       0
32       bNumEndpoints           2
33       bInterfaceClass         2 Communications
34       bInterfaceSubClass      2 Abstract (modem)
35       bInterfaceProtocol      1 AT-commands (v.25ter)
36       iInterface              2 USB COMMUNICATION BRIDGE
37       Endpoint Descriptor:
38         bLength                 7
39         bDescriptorType         5
40         bEndpointAddress     0x81  EP 1 IN
41         bmAttributes            3
42           Transfer Type            Interrupt
43           Synch Type               None
44           Usage Type               Data
45         wMaxPacketSize     0x0010  1x 16 bytes
46         bInterval             100
47       Endpoint Descriptor:
48         bLength                 7
49         bDescriptorType         5
50         bEndpointAddress     0x01  EP 1 OUT
51         bmAttributes            3
52           Transfer Type            Interrupt
53           Synch Type               None
54           Usage Type               Data
55         wMaxPacketSize     0x0010  1x 16 bytes
56         bInterval             255
57       CDC Header:
58         bcdCDC               1.10
59       CDC ACM:
60         bmCapabilities       0x06
61           sends break
62           line coding and serial state
63       CDC Union:
64         bMasterInterface        0
65         bSlaveInterface         1 
66       CDC Call Management:
67         bmCapabilities       0x03
68           call management
69           use DataInterface
70         bDataInterface          1
71     Interface Descriptor:
72       bLength                 9
73       bDescriptorType         4
74       bInterfaceNumber        1
75       bAlternateSetting       0
76       bNumEndpoints           2
77       bInterfaceClass        10 CDC Data
78       bInterfaceSubClass      0 Unused
79       bInterfaceProtocol      0 
80       iInterface              2 USB COMMUNICATION BRIDGE
81       Endpoint Descriptor:
82         bLength                 7
83         bDescriptorType         5
84         bEndpointAddress     0x82  EP 2 IN
85         bmAttributes            2
86           Transfer Type            Bulk
87           Synch Type               None
88           Usage Type               Data
89         wMaxPacketSize     0x0040  1x 64 bytes
90         bInterval               0
91       Endpoint Descriptor:
92         bLength                 7
93         bDescriptorType         5
94         bEndpointAddress     0x03  EP 3 OUT
95         bmAttributes            2
96           Transfer Type            Bulk
97           Synch Type               None
98           Usage Type               Data
99         wMaxPacketSize     0x0040  1x 64 bytes
100         bInterval               0
101 Device Status:     0x0000
102   (Bus Powered)